SYSTEM ARCHITECTURE



           CONNECTION POSSIBILITIES TO YOUR IT ENVIRONMENT

                                                                                                                                   YOUR ERP (SAP), ASSISTANCE SYSTEMS, ...



           YOUR MACHINES / SYSTEMS

           with OPC UA
                                                                                                                                                                     GRX-OPC UA - SERVER & DATABASE

                                                                                                                                                                     - OPC UA server                     - historisation
                                                                                                                                                                     - OPC client for additional systems  - limit value monitoring per
                                                                                                                                                                        (e.g. ERP)                          - secure database machine and
                                                                                                                                                                     - optional hot standby redundancy     cycle
                                                                                                                                                                     - user administration & access

                                                                                                                                                                        security



                                                                                     GRINDAIX (GRX)

                                                                                         PRODUCTS                                                                                                GRX-DASHBOARD

                                                                                                                                                                                                           - web client
                                                                                                                                                                                                           - (customised) dashboard
                                                                                                                                                                                                           - limit value monitoring

           YOUR MACHINES / SYSTEMS                                                  GRX-      COLLECTOR                                                                                                    - no installation
           without OPC UA                                       CONDITION                                                                                                                                  - device independence
                                                                   GUARD                            BOX




                                                                                                                                                                                         OTHER OPC UA SYSTEMS
                                                                                                                                                                                       (I/O LINK MASTER, QUALITY
                                                                - 6 analog M12 slots         - 7 inputs for max. 7
                                                                - 1 PT 100 slot                Condition Guards                                                                                     SYSTEMS, ...)
                                                                - 6 digital inputs
                                                                - 4 digital outputs




                                                                                                                                                                   GRX-CONDITION MONITORING SYSTEM


                                                                                                                                                                                           - OPC UA Interface
                               ?                       Operating status feedback                                                                                                           - A/D conversion of the measurement data

                                                  Communication via switching signals                                                                                                      - connection of manufacturer-independent
                                                                                                                                                                                             sensor technology
                                                    Acquisition of the sensor signals
                                                                                                 Grindaix Sensor                                                                           - connection of existing analogue sensors
                                                                                                      GRX-Q
                                  all commercially                                                                                                                                         - freely expandable
                            available analogue sensors
                                                                                                                                                                                           - feedback of the operating status to
                                                                                                                                                                                             machines or signal lamps
   15   16   17   18   19   20   21   22   23   24