Page 77 - Grindaix-product-catalogue-english
P. 77

LUBRICOOLANT SYSTEM COMPONENTS                                                       LUBRICOOLANT SYSTEM COMPONENTS

 LUBRICOOLANT PUMPS  LUBRICOOLANT


          PRESSURE DEVICES


 At Grindaix we know the exact lubricoolant requirements of your machine tools.
 Based on this knowledge, we are able to design the pressure supply technology
 efficiently. This saves you unnecessary waste with overdimensioning or avoids   Grindaix pressure transmitters are high-performance transmitters based on a microprocessor with flexible pressure
 undersupply of your machining site and associated thermal damage of your   calibration and flexible output, achieving automatic compensation of ambient temperature and process variables. The
 parts. We supply all common lubricoolant pump technologies for low-pres-  HART protocol may be used to communicate with the device and to configure various parameters. All sensor data is
 sure and high-pressure applications, and gladly also in combination with our   fed into, modified and saved in the EEPROM.
 Grindaix nozzles.
          The electronic module shown as an example here consists of a sealed circuit board inside a housing. The transmitter
 Would you like to know whether a frequency-controlled pump is the right   consists of a microprocessor control unit, as well as an analogue, an LCD and a connection module.
 choice for your technical application? We would be happy to answer this ques-
 tion. Following a Coolant Audit® (see Services chapter), we select the pump that
 is suitable for your applications and calculate the return on investment period.
 In so doing, we take into account the applications in your central units as well
 as the pressure boosting stations on individual machines or machine groups.



 ADVANTAGES     ADVANTAGES


 Needs-based pump selection  Pressure sensors specially developed
               for the working area (oil-tight)
 Stationary and/or frequency-controlled
               Long-term stability
 All common pump types
               High measuring span ratio (100:1)
 Maximum robustness in lubricoolant operation
               Automatic ambient temperature compensation

               Measurement of overpressure and absolute pressure

               High reference accuracy +/- 0.075 % of the calibrated span





 Pump characteristic curve
 Pumpenkennlinie

 20
 18
 16
 Pump characteristic curve
 14  Operating point
 Pressure (bar) Druck  [bar]  10
 12



 8
 6

 4
 System characteristic curve
 2

 0
 0  50  100  150  200  250  300
 Volume flow (l/min)
 Volumenstrom [l/min]


 76                                                                                                          77