Page 67 - Grindaix-product-catalogue-english
P. 67

MEASUREMENT AND CONTROL SYSTEMS                                                      MEASUREMENT AND CONTROL SYSTEMS


 COOLANT POINTER  COOLANT DISPLAY




 Our Coolant Pointer allows you to see directly whether your Grindaix needle nozzle is correctly positioned. Two laser diodes show you   Our Coolant Display is operated with a pressure sensor at the nozzle. By means of the integrated Grindaix lubricoolant characteristic
 whether the angle of inclination and the spraying direction are correct. When operating the nozzles, it is often almost impossible to check   curve, the interaction of pressure, lubricoolant exit speed and the current lubricoolant flow rate can be displayed in real time based on
 whether the nozzle setting is correct due to the high lubricoolant spray effects. There is now a simple solution to this!  the knowledge of the exact nozzle characteristic curve. Following successful installation of the Grindaix pressure sensor, a cable is routed
          out of the machine, the machine is started and the lubricoolant data is read – DONE!




 “We can make your                  “Simply read off your


 lubricoolant supply visible.”   lubricoolant exit speed.”




 Faulty alignment



                ADVANTAGES


               Display of lubricoolant pressure, volume flow
               and exit speed

               Recognises the Grindaix nozzle and its specific
               characteristic curve (p, Q, > lubricoolant exit speed)

               Easy assembly
 Correct alignment
               Very easy handling (plug & play)

               Can be used on all grinding machines
               Upload of characteristic curves via USB interface,
               dataset sent by email









 ADVANTAGES  SPECIFICATIONS                                          SPECIFICATIONS

                                                                    WxHxD: 153 x 130 x 37 mm
 Visualises lubricoolant impact point by means of a   WxHxD: 125 x 133 x 40 mm
 laser beam
                                                                    Housing: die-cast aluminium
 Housing: die-cast aluminium, incl. magnetic base for
 Displays lubricoolant impact point on your tool/part
 quick mounting
                                                                    Power supply: 24 V DC, 6 W
 Checks the correct nozzle position (angle, distance,   Protection class: IP44 (splash-proof), class 2 laser, power
 supply point)  below 1 mW, EN 60825-1:2007                         Pressure sensor input: [0 (4) - 20] mA
 Checks the position of profiled Grindaix nozzles   Power supply: 3x AA batteries (Mignon)
 through the simultaneous use of 2 Grindaix laser units             Sensor connection: via supplied cable (push/pull) M12
 on one nozzle  Laser connection: ODU mini snap (cable included,
 Simple handling: attach to the needle nozzle, switch   length 1.5 m), up to two lasers can be connected  Pressure range: selectable according
                                                                    to DIN, e.g. [0 - 10] bar
 on – READY!
 Available for all nozzle geometries (needle diameter: 3,           Grindaix nozzle data exchange: via USB interface
 4 or 5 mm)
                                                                    Display: resistive 3.5” touch panel, full colour

                                                                    Protection class: IP44


 66                                                                                                          67
   62   63   64   65   66   67   68   69   70   71   72