Page 62 - Grindaix-product-catalogue-english
P. 62

MEASUREMENT AND CONTROL SYSTEMS                                                                                                                                                                     MEASUREMENT AND CONTROL SYSTEMS
          SYSTEM ARCHITECTURE




          CONNECTION POSSIBILITIES

          TO YOUR IT ENVIRONMENT                                                                                                     YOUR ERP (SAP), ASSISTANCE SYSTEMS, ...



          YOUR MACHINES / SYSTEMS

          with OPC UA
                                                                                                                                                                     GRX-OPC UA - SERVER & DATABASE

                                                                                                                                                                     - OPC UA server                     - historisation
                                                                                                                                                                     - OPC client for additional systems  - limit value monitoring per
                                                                                                                                                                        (e.g. ERP)                          - secure database machine and
                                                                                                                                                                     - optional hot standby redundancy     cycle
                                                                                                                                                                     - user administration & access
                                                                                                                                                                        security




                                                                                 GRINDAIX (GRX)

                                                                                      PRODUCTS                                                                                                 GRX-DASHBOARD

                                                                                                                                                                                                          - web client
                                                                                                                                                                                                          - (customised) dashboard
                                                                                                                                                                                                          - limit value monitoring
         YOUR MACHINES / SYSTEMS                                                   GRX-       COLLECTOR                                                                                                   - no installation

         without OPC UA                                          CONDITION                                                                                                                                - device independence
                                                                    GUARD                          BOX




                                                                                                                                                                                        OTHER OPC UA SYSTEMS
                                                                                                                                                                                     (I/O LINK MASTER, QUALITY
                                                               - 6 analog M12 slots         - 7 inputs for max. 7
                                                               - 1 PT 100 slot                Condition Guards                                                                                    SYSTEMS, ...)
                                                               - 6 digital inputs
                                                               - 4 digital outputs




                                                                                                                                                                  GRX-CONDITION MONITORING SYSTEM



                             ?                        Operating status feedback                                                                                                           - OPC UA Interface
                                                                                                                                                                                          - A/D conversion of the measurement data
                                                Communication via switching signals
                                                                                                                                                                                          - connection of manufacturer-independent
                                                  Acquisition of the sensor signals                                                                                                         sensor technology
                                                                                                Grindaix-Sensor
                                                                                                    GRX-Q                                                                                 - connection of existing analogue sensors
                                all commercially
                           available analogue sensors                                                                                                                                     - freely expandable
                                                                                                                                                                                          - feedback of the operating status to
                                                                                                                                                                                            machines or signal lamps



          62                                                                                                                                                                                                                        63