Page 62 - Grindaix-product-catalogue-english
P. 62
MEASUREMENT AND CONTROL SYSTEMS MEASUREMENT AND CONTROL SYSTEMS
SYSTEM ARCHITECTURE
CONNECTION POSSIBILITIES
TO YOUR IT ENVIRONMENT YOUR ERP (SAP), ASSISTANCE SYSTEMS, ...
YOUR MACHINES / SYSTEMS
with OPC UA
GRX-OPC UA - SERVER & DATABASE
- OPC UA server - historisation
- OPC client for additional systems - limit value monitoring per
(e.g. ERP) - secure database machine and
- optional hot standby redundancy cycle
- user administration & access
security
GRINDAIX (GRX)
PRODUCTS GRX-DASHBOARD
- web client
- (customised) dashboard
- limit value monitoring
YOUR MACHINES / SYSTEMS GRX- COLLECTOR - no installation
without OPC UA CONDITION - device independence
GUARD BOX
OTHER OPC UA SYSTEMS
(I/O LINK MASTER, QUALITY
- 6 analog M12 slots - 7 inputs for max. 7
- 1 PT 100 slot Condition Guards SYSTEMS, ...)
- 6 digital inputs
- 4 digital outputs
GRX-CONDITION MONITORING SYSTEM
? Operating status feedback - OPC UA Interface
- A/D conversion of the measurement data
Communication via switching signals
- connection of manufacturer-independent
Acquisition of the sensor signals sensor technology
Grindaix-Sensor
GRX-Q - connection of existing analogue sensors
all commercially
available analogue sensors - freely expandable
- feedback of the operating status to
machines or signal lamps
62 63