MEASUREMENT AND CONTROL SYSTEMS                                                      MEASUREMENT AND CONTROL SYSTEMS
 SYSTEM ARCHITECTURE




 CONNECTION POSSIBILITIES

 TO YOUR IT ENVIRONMENT  YOUR ERP (SAP), ASSISTANCE SYSTEMS, ...



 YOUR MACHINES / SYSTEMS

 with OPC UA
                                              GRX-OPC UA - SERVER & DATABASE

                                              - OPC UA server                     - historisation
                                              - OPC client for additional systems  - limit value monitoring per
                                                 (e.g. ERP)                          - secure database machine and
                                              - optional hot standby redundancy     cycle
                                              - user administration & access
                                                 security




 GRINDAIX (GRX)

 PRODUCTS                                                               GRX-DASHBOARD

                                                                                   - web client
                                                                                   - (customised) dashboard
                                                                                   - limit value monitoring
 YOUR MACHINES / SYSTEMS   GRX-  COLLECTOR                                         - no installation

 without OPC UA  CONDITION                                                         - device independence
 GUARD  BOX




                                                                 OTHER OPC UA SYSTEMS
                                                              (I/O LINK MASTER, QUALITY
 - 6 analog M12 slots  - 7 inputs for max. 7
 - 1 PT 100 slot    Condition Guards                                       SYSTEMS, ...)
 - 6 digital inputs
 - 4 digital outputs




                                           GRX-CONDITION MONITORING SYSTEM



 ?  Operating status feedback                                      - OPC UA Interface
                                                                   - A/D conversion of the measurement data
 Communication via switching signals
                                                                   - connection of manufacturer-independent
 Acquisition of the sensor signals                                   sensor technology
 Grindaix-Sensor
 GRX-Q                                                             - connection of existing analogue sensors
 all commercially
 available analogue sensors                                        - freely expandable
                                                                   - feedback of the operating status to
                                                                     machines or signal lamps