As a turnkey project, we work with our renowned partners—such as DIW Voith, WISAG, Bosch Rexroth, and many others—to provide you with a comprehensive package that includes the installation and commissioning of complete cooling lubricant supply systems. This ensures that your optimized machine is ready for immediate use with minimal effort on your part.
Once the COOLANT AUDIT has been successfully completed, you will have a clear understanding of your potential for improvement. We will design the ideal retrofit kit for you and put together a cost-effective and efficient package consisting of needle nozzles, gFlex, Coolant Products, and much more—tailored entirely to your needs. After retrofitting your machine, we will work with you to get it back up and running as quickly as possible.
We also work at night and on weekends, saving you valuable production time!
Case Studies - Nozzle Retrofit for Machine Tools
Below is a small selection of retrofitted machines. If you are interested in a nozzle retrofit, please send us a non-binding email with the machine model to info@grindaix.deoder or call us at 02273 953730. We would be happy to provide you with a customized quote.
TACCHELLA - Proflex 3
External cylindrical grinding
The TACCELLA PROFLEX 3 grinding machine experienced several issues upon delivery, including heavy smoke in the work area, grinding burn, and excessive wear on the grinding wheels. This was caused by inadequate cooling, which was attributable to an unfavorable spray pattern from the nozzles installed by the machine manufacturer. By using grindaix nozzles, such as the slot nozzle or the ND-40-Flex_G, for targeted component cooling and effective quenching of the spark jet, these problems were completely resolved. At the same time, the maximum coolant flow rate was achieved with the existing pumps. As a result, the scrap rate dropped significantly, smoke formation was prevented, and the grinding process was stabilized overall.
LANDIS - LT1
Camshaft grinding
The coolant supply for the LANDIS LT1 grinding machine was optimized with the aim of increasing tool life, reducing cycle times, and reliably preventing grinding burn and burr formation. To achieve this, an ND pump was first installed, as only a central pressure of 5 bar had previously been available. In addition, the nozzle design in the grinding supply system was optimized through the targeted use of needle nozzles and the installation of grindaix cleaning nozzles. These measures significantly improved the cooling and cleaning performance while simultaneously reducing the coolant requirement from the original 260 l/min to 194 l/min.
ABA - SLM V2
Profile grinding
For the aba SLM V2 grinding machine, the coolant requirement per individual machine was reduced to such an extent that the investment of approximately 2.5 million euros in a new filtration system and facility (the old system was at capacity, but six additional machines were to be added to the line) was no longer necessary. In addition, thermal issues during face grinding were resolved through the use of needle nozzles, such as the profiled needle nozzle or the Grindaix cleaning nozzle. The right combination of our nozzle technology with our selection of the appropriate pump led to immediate success. This not only significantly improved the cooling and cleaning effects but also reduced the coolant requirement from 634 l/min to 351 l/min.
BUDERUS - CNC 235
Bore, face, and cylindrical grinding
The main issue with the audited Buderus CNC 235 grinding machine was the short service life of the corundum grinding wheels on spindle 2 during bore grinding and the resulting setup times. However, following the audit, improvements to the coolant nozzle system were successfully implemented for all three grinding operations. A needle nozzle was installed for internal cylindrical grinding, along with the ND-40-Flex_G, reducing coolant consumption from 181 l/min to 98 l/min and annual energy consumption from 63,500 kWh to 9,500 kWh. The cost reductions resulting from improved tool life, productivity, and lower scrap rates led to an extremely short return on investment (ROI).
GLEASON PFAUTER - P4500
Gear grinding
The problem with this GLEASON PFAUTER grinding machine was that its coolant consumption was so high that the coolant filtration system had to be significantly oversized. This resulted in unnecessarily high energy costs, despite existing shortcomings in the coolant’s cleaning performance. As part of the optimization, the existing grinding and flushing nozzles were replaced with grindaix nozzles, and a mechanical throttling device was additionally integrated upstream of the flushing nozzles. In addition, the existing pressure booster pump was replaced with a smaller, frequency-controlled ND pump. This will enable a demand-based coolant supply in the future when switching to ND-30(60) Flex_G needle nozzles—adapted to the respective module (m = 10–36). As a result of the implemented measures, the coolant requirement was significantly reduced from 932 l/min to 568 l/min. At the same time, the annual energy consumption dropped from 102,980 kWh to 51,490 kWh, leading to a substantial reduction in operating costs.
EMAG - VTC 315
External cylindrical grinding
On the EMAG VTC grinding machine, the coolant supply was specifically optimized to improve both the process and energy efficiency. By using a frequency-controlled low-pressure pump instead of conventional control valves, the flow rate of the cooling lubricant was significantly reduced. As a result, less cooling capacity was required, leading to noticeable energy savings. In addition, the cleaning of the grinding wheel was effectively improved through the use of the Grindaix RD-104 cleaning nozzle, thereby increasing process stability. Overall, annual energy consumption was reduced from 23,800 kWh to 18,100 kWh.